Monitoring System Components
Monitoring Components and Identifying SNMP Messages
253
■
“System Board Components” on page 259
■
“System Firmware Components” on page 261
■
“Hard Disk Drive Components” on page 262
System Chassis Components
The following table lists the system chassis components.
Component Name
(Oracle ILOM CLI
Targets)
IPMI
Type
Description
Values (if applicable)
/
SYS
FRU
Product information only
/SYS/
UUID
FRU
Unique system ID
Derived from host MAC address. Used for PXE
boot and licensing.
/SYS/
ACPI
State
sensor
Advanced Configuration
and Power Interface
(
hidden
)
01h-ACPI_ON_WORKING
20h-ACPI_SOFT_OFF
/SYS/
VPS
Threshold
sensor
Virtual power sensor
Watts
/SYS/
VPS_CPUS
Threshold
sensor
Virtual power sensor
(CPUs)
Watts
/SYS/
VPS_MEMORY
Threshold
sensor
Virtual power sensor
(Memory)
Watts
/SYS/
VPS_FANS
Threshold
sensor
Virtual power sensor
(Fans)
Watts
/SYS/
INTSW
Discrete
sensor
Chassis intrusion switch
01h-Deasserted
02h-Asserted
/SYS/
T_AMB
Threshold
sensor
Ambient temperature
on system motherboard,
located on the front
indicator module (FIM).
Degrees Celsius
/SYS/
TEMP_FAULT
Indicator Temperature Fault LED
Color: Amber
Location: Front panel
Off: Normal
On: Chassis overtemp fault
/SYS/
OK
Indicator Power/OK LED
Color: Green
Location: Front panel
Off: Power is off or the Oracle ILOM boot is not
complete.
Summary of Contents for EXADATA X6-2
Page 1: ...Part No E62171 02 June 2016 Oracle Server X6 2 Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X6 2 Service Manual June 2016 ...
Page 62: ...62 Oracle Server X6 2 Service Manual June 2016 ...
Page 226: ...226 Oracle Server X6 2 Service Manual June 2016 ...
Page 278: ...278 Oracle Server X6 2 Service Manual June 2016 ...
Page 284: ...284 Oracle Server X6 2 Service Manual June 2016 ...