Install the Internal HBA SAS Cable Assembly
176
Oracle Server X6-2 Service Manual • June 2016
a.
Remove the PCIe riser from PCIe slot 3 and 4.
See
“Remove the PCIe Riser From PCIe Slots 3 and 4” on page 103
b.
On the under side of the HBA, card press the SAS cable connector latches
and then pull out the connectors [2].
c.
On the under side of the HBA card, grasp the super capacitor connector and
pull it out [2].
6.
Disconnect the super capacitor cable from the super capacitor [3].
7.
Carefully remove the SAS cables and the super capacitor cable from the server.
Related Information
■
“Install the Internal HBA SAS Cable Assembly” on page 176
Install the Internal HBA SAS Cable Assembly
Caution -
The internal HBA SAS cable assembly should be installed only by an Oracle
qualified service technician.
1.
Carefully guide SAS cables and the super capacitor cable along the side of the
chassis.
See
.
2.
Connect the super capacitor cable to the super capacitor [3].
3.
Connect the SAS cables the super capacitor cable to the internal HBA card. [2}
4.
Install the SAS cables into the disk backplane [1].
5.
Install the PCIe riser with the internal HBA card into PCIe slot 3.
See
“Install the PCIe Riser Into PCIe Slots 3 and 4” on page 105
6.
Install all of the server fan modules.
See
“Install a Fan Module” on page 79
7.
Return the server to operation.
Summary of Contents for EXADATA X6-2
Page 1: ...Part No E62171 02 June 2016 Oracle Server X6 2 Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X6 2 Service Manual June 2016 ...
Page 62: ...62 Oracle Server X6 2 Service Manual June 2016 ...
Page 226: ...226 Oracle Server X6 2 Service Manual June 2016 ...
Page 278: ...278 Oracle Server X6 2 Service Manual June 2016 ...
Page 284: ...284 Oracle Server X6 2 Service Manual June 2016 ...