Remove the Server From the Rack
58
Oracle Server X6-2 Service Manual • June 2016
4.
While the release latch covers are in the open position, slowly pull the server
forward until the slide-rails latch into a locked position [2].
The server is now in the extended maintenance position. .
Related Information
■
“Disconnect Cables From the Server” on page 56
■
“Remove the Server From the Rack” on page 58
■
“Reinstall the Server Into the Rack” on page 190
Remove the Server From the Rack
Caution -
The server weighs approximately 18.1 kg (40.0 lbs). Two people are required to
dismount and carry the chassis.
1.
Disconnect all the cables and power cords from the server.
2.
Remove the cable management arm (CMA).
For instructions for removing the CMA, see the
“Remove the Cable Management Arm” in
Oracle Server X6-2 Installation Guide
3.
Extend the server to the maintenance position.
“Extend the Server to the Maintenance Position” on page 56
4.
From the front of the server, pull the green slide-rail release tabs toward the front
of the server, and pull the server out of the rack until it is free of the rack rails.
A slide-rail release tab is located on each slide-rail (see
[frame 2]).
Note -
To pull the green slide-rail release tab, place your finger in the center of the tab, not on
the end, and apply pressure as you pull the tab toward the front of the server.
5.
Set the server on a sturdy work surface.
Related Information
■
“Disconnect Cables From the Server” on page 56
■
“Take Antistatic Measures” on page 59
■
“Extend the Server to the Maintenance Position” on page 56
■
Summary of Contents for EXADATA X6-2
Page 1: ...Part No E62171 02 June 2016 Oracle Server X6 2 Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X6 2 Service Manual June 2016 ...
Page 62: ...62 Oracle Server X6 2 Service Manual June 2016 ...
Page 226: ...226 Oracle Server X6 2 Service Manual June 2016 ...
Page 278: ...278 Oracle Server X6 2 Service Manual June 2016 ...
Page 284: ...284 Oracle Server X6 2 Service Manual June 2016 ...