Servicing the DIMMs (CRU)
Servicing CRUs That Require Server Power-Off
91
FIGURE 18
DIMM Population Order for Dual-Processor Systems
The following table describes the proper order in which to install DIMMs in a dual-processor
system using the numbered callouts in the above figure, the memory channels labels (Ch A
through Ch D), and the DIMM socket labels (D0 through D11).
TABLE 13
DIMM Population Order for Dual-Processor Systems
Population Order
DIMM Sockets for Processor
0 (P0)
DIMM Sockets for Processor 1
(P1)
Memory Channels
Fill the black sockets first (alternating between processor 0 and processor 1)
First
Fill D0 first
Then fill D0
Ch C
Second
Fill D11 first
Then fill D11
Ch A
Third
Fill D3 first
Then fill D3
Ch D
Fourth
Fill D8 first
Then fill D8
Ch B
Then fill the black sockets with white tabs (alternating between processor 0 and processor 1)
Fifth
Fill D1 first
Then fill D1
Ch C
Sixth
Fill D10 first
Then fill D10
Ch A
Seventh
Fill D4 first
Then fill D4
Ch D
Eighth
Fill D7 first
Then fill D7
Ch B
Then fill the white sockets (alternating between processor 0 and processor 1)
Ninth
Fill D2 first
Then fill D2
Ch C
Tenth
Fill D9 first
Then fill D9
Ch A
Eleventh
Fill D5 first
Then fill D5
Ch D
Summary of Contents for EXADATA X6-2
Page 1: ...Part No E62171 02 June 2016 Oracle Server X6 2 Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X6 2 Service Manual June 2016 ...
Page 62: ...62 Oracle Server X6 2 Service Manual June 2016 ...
Page 226: ...226 Oracle Server X6 2 Service Manual June 2016 ...
Page 278: ...278 Oracle Server X6 2 Service Manual June 2016 ...
Page 284: ...284 Oracle Server X6 2 Service Manual June 2016 ...