Servicing the NVMe Cables
Servicing FRUs
177
a.
Install the server top cover.
“Install the Server Top Cover” on page 188
.
b.
Close the server fan door.
c.
Return the server to the normal rack position.
“Return the Server to the Normal Rack Position” on page 191
d.
Reconnect the data cables to the server and reconnect the power cords to
the server power supplies.
“Reconnect Data Cables and Power Cords” on page 193
e.
Power on the server.
“Power On the Server” on page 194
.
Verify that the Power/OK status indicator is steady on.
Related Information
■
“Remove the Internal HBA SAS Cable Assembly” on page 173
Servicing the NVMe Cables
Caution -
The NVMe cables should be serviced only by authorized Oracle Services personnel.
Caution -
These procedures require that you handle components that are sensitive to
electrostatic discharge. This sensitivity can cause the components to fail. To avoid
damage, ensure that you follow antistatic practices as described in
Caution -
The system supplies power to the cables even when the server is powered off.
To avoid personal injury or damage to the server, you must disconnect power cords before
servicing the cables.
This section covers the following procedures:
■
“Removing the NVMe Cables” on page 178
■
Summary of Contents for EXADATA X6-2
Page 1: ...Part No E62171 02 June 2016 Oracle Server X6 2 Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X6 2 Service Manual June 2016 ...
Page 62: ...62 Oracle Server X6 2 Service Manual June 2016 ...
Page 226: ...226 Oracle Server X6 2 Service Manual June 2016 ...
Page 278: ...278 Oracle Server X6 2 Service Manual June 2016 ...
Page 284: ...284 Oracle Server X6 2 Service Manual June 2016 ...