Remove and Install Filler Panels
188
Oracle Server X6-2 Service Manual • June 2016
Remove and Install Filler Panels
See the procedures in the following table to remove and install filler panels for
storage drives and PCIe cards.
Filler Panel
Type
Removal Procedure
Installation Procedure
Storage Drive 1. Locate the storage drive filler panel to be
removed from the server.
2. To unlatch the storage drive filler panel, pull
the release lever, and then tilt the lever out
into a fully opened position.
3. To remove the filler panel from the slot, hold
the opened release lever, and gently slide the
filler panel toward you.
1. Locate the vacant storage drive module slot
in the server, and then ensure that the release
lever on the filler panel is fully opened.
2. Slide the filler panel into the vacant slot
by pressing the middle of the filler panel
faceplate with your thumb or finger.
3. The release lever will close as it makes
contact with the chassis. Do not slide the
filler panel in all the way. Leave the filler
panel out approximately 0.25 to 0.50 inch (6
to 12 mm) from the opening.
4. Using your thumb or finger, press on the
middle of the filler panel faceplate until the
release lever engages with the chassis.
5. Close the release lever until it clicks into
place and is flush with the front of the server
PCI Slot
1. Remove the server top cover.
2. To remove the PCIe slot filler panel, rotate
the PCIe locking mechanism, and then lift
and remove the PCIe slot filler panel from the
location into which you intend to install the
PCIe card.
Note:
In single-processor systems,
PCIe slot 1 is nonfunctional; therefore, there
is no need to remove the filler panel for slot 1
1. Remove the server top cover.
2. To install the PCIe slot filler panel, press the
PCIe filler panel into the vacant PCIe slot,
and then rotate the PCIe locking mechanism
to secure the PCIe slot filler panel.
Note:
In single-processor systems, PCIe slot 1 is
nonfunctional; therefore, the server ships
with this filler panel installed.
Install the Server Top Cover
1.
Open the server fan door.
See
“Open the Server Fan Door” on page 59
2.
Place the top cover on the chassis [1].
Place the cover down so that it hangs over the rear of the server by about 13 mm (0.5 inches)
and the side latches align with the slots in the sides of the chassis.
Note -
There are three latching tabs on the sides of the cover, two on the right side and one on
the left side (viewing the server from the front). There is also a latch on the underside of the
cover in the front left corner.
Summary of Contents for EXADATA X6-2
Page 1: ...Part No E62171 02 June 2016 Oracle Server X6 2 Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X6 2 Service Manual June 2016 ...
Page 62: ...62 Oracle Server X6 2 Service Manual June 2016 ...
Page 226: ...226 Oracle Server X6 2 Service Manual June 2016 ...
Page 278: ...278 Oracle Server X6 2 Service Manual June 2016 ...
Page 284: ...284 Oracle Server X6 2 Service Manual June 2016 ...