Power On an NVMe Storage Drive and Attach a Device Driver
Servicing CRUs That Do Not Require Server Power-Off
75
2.
If necessary, remove the drive filler panel.
3.
Align the replacement drive with the drive slot.
The drive is physically addressed according to the slot in which it is installed. It is important to
install a replacement drive in the same slot as the drive that was removed.
4.
Slide the drive into the slot until the drive is fully seated.
.
5.
Close the drive latch to lock the drive in place [2].
.
Power On an NVMe Storage Drive and Attach a Device Driver
To power on the slot and attach the device driver, type:
#
echo 1 /sys/bus/pci/slots/
$slot
/power
Where
$slot
is the slot number for the NVMe storage drive.
Verify Operation of an NVMe Storage Drive
To verify that an NVMe drive is operating properly, do one of the following:
■
Check the
/var/log/messages
log file.
■
Type: #
ls -l /dev/nvme*
.
Related Information
■
“Storage Drive Status Indicators” on page 65
■
“Storage Drives Hot-Plug Conditions” on page 64
■
“Storage Drive Failure and RAID” on page 64
■
“Storage Drive Locations and Numbering” on page 64
Servicing Fan Modules (CRU)
The fan modules are located in the front of the server. See the following procedures:
■
“Remove a Fan Module” on page 76
■
Summary of Contents for EXADATA X6-2
Page 1: ...Part No E62171 02 June 2016 Oracle Server X6 2 Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X6 2 Service Manual June 2016 ...
Page 62: ...62 Oracle Server X6 2 Service Manual June 2016 ...
Page 226: ...226 Oracle Server X6 2 Service Manual June 2016 ...
Page 278: ...278 Oracle Server X6 2 Service Manual June 2016 ...
Page 284: ...284 Oracle Server X6 2 Service Manual June 2016 ...