Monitoring System Components
254
Oracle Server X6-2 Service Manual • June 2016
Component Name
(Oracle ILOM CLI
Targets)
IPMI
Type
Description
Values (if applicable)
Standby blink: Standby power is on, but the
chassis power is off and the Oracle ILOM SP is
running.
Slow blink: Startup sequence has been initiated
on the host.
Steady on: Server is powered on and the host is
booting OS or the host is running the OS.
/SYS/
SERVICE
Indicator Service Required LED
Color: Amber
Location: Front panel
Off: Normal
On: Server requires service.
/SYS/
LOCATE
Indicator Locator LED
Color: White
Location: Front and rear panels
Off: Normal
Fast blink: Locate function is activated; self-
extinguishes after 30 minutes.
/SYS/
HOST_ERR
Discrete
sensor
Host asserted error sensor
01h-Deasserted
02h-Asserted
/SYS/
PS_FAULT
Indicator Rear Power Supply Fault
LED
Color: Amber
Location: Mainboard
Off: Normal
On: General power supply fault
/SYS/
FAN_FAULT
Indicator Top Fan Fault LED
Color: Amber
Location: Mainboard
Off: Normal
On: General fan fault
Related Information
■
“Cooling Unit Components” on page 255
■
“Disk Backplane Components” on page 255
■
“Memory Device Components” on page 256
■
“Power Unit Components” on page 257
■
“Processor Components” on page 258
■
Summary of Contents for EXADATA X6-2
Page 1: ...Part No E62171 02 June 2016 Oracle Server X6 2 Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X6 2 Service Manual June 2016 ...
Page 62: ...62 Oracle Server X6 2 Service Manual June 2016 ...
Page 226: ...226 Oracle Server X6 2 Service Manual June 2016 ...
Page 278: ...278 Oracle Server X6 2 Service Manual June 2016 ...
Page 284: ...284 Oracle Server X6 2 Service Manual June 2016 ...