Remove the Front Indicator Module
Servicing FRUs
159
Caution -
Ensure that all power is removed from the server before removing or installing a front
indicator module. You must disconnect the power cables from the server before performing
these procedures.
Follow these procedures to remove and install the front indicator module (FIM).
■
“Remove the Front Indicator Module” on page 159
■
“Install the Front Indicator Module ” on page 161
Related Information
■
“Disconnect Cables From the Server” on page 56
■
“Remove the Server From the Rack” on page 58
■
“Take Antistatic Measures” on page 59
■
“Open the Server Fan Door” on page 59
Remove the Front Indicator Module
Caution -
The front indicator module should be removed only by authorized Oracle Services
personnel.
1.
Prepare the server for service.
a.
Power off the server and disconnect the power cords from the power
supplies.
“Powering Down the Server” on page 51
.
b.
Extend the server to the maintenance position.
“Extend the Server to the Maintenance Position” on page 56
.
c.
Attach an antistatic wrist strap to your wrist, and then to a metal area on the
chassis.
“Take Antistatic Measures” on page 59
.
2.
To remove the top cover from the storage drive cage, do the following [1]:
a.
Remove the six Phillips screws from the top of the storage drive cage.
There are three Phillips screws on each side of the storage drive cage.
b.
Open the server fan door.
Summary of Contents for EXADATA X6-2
Page 1: ...Part No E62171 02 June 2016 Oracle Server X6 2 Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X6 2 Service Manual June 2016 ...
Page 62: ...62 Oracle Server X6 2 Service Manual June 2016 ...
Page 226: ...226 Oracle Server X6 2 Service Manual June 2016 ...
Page 278: ...278 Oracle Server X6 2 Service Manual June 2016 ...
Page 284: ...284 Oracle Server X6 2 Service Manual June 2016 ...