Memory Events
Monitoring Components and Identifying SNMP Messages
273
Messages and Descriptions
Component Name
Oracle ILOM Event Message:
event fault.memory.intel.mrc.unknown-errcode "An unknown
error code from the Memory Reference Code (MRC) has been detected."
Severity and Description:
Informational; A memory component fault has been cleared.
SNMP Trap:
sunHwTrapMemoryFault
Oracle ILOM Event Message:
event fault.memory.intel.dimm.udimm-unsupported "An
unbuffered memory DIMM (UDIMM) has been detected."
Severity and Description:
Major; A memory component is suspected of causing a fault.
/SYS/MB/P[0-x]/D[0-11]
SNMP Trap:
sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message:
event fault.memory.intel.dimm.udimm-unsupported "An
unbuffered memory DIMM (UDIMM) has been detected."
Severity and Description:
Informational; A memory component fault has been cleared.
/SYS/MB/P[0-x]/D[0-11]
SNMP Trap:
sunHwTrapMemoryFault
Oracle ILOM Event Message:
event fault.memory.intel.dimm.sodimm-unsupported "An
unsupported SODIMM has been detected in system."
Severity and Description:
Major; A memory component is suspected of causing a fault.
/SYS/MB/P[0-x]/D[0-11]
SNMP Trap:
sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message:
event fault.memory.intel.dimm.sodimm-unsupported "An
unsupported SODIMM has been detected in system."
Severity and Description:
Informational; A memory component fault has been cleared.
/SYS/MB/P[0-x]/D[0-11]
SNMP Trap:
sunHwTrapMemoryFault
Oracle ILOM Event Message:
event fault.memory.intel.dimm.4gb-fused "An unsupported 4-gb
memory DIMM has been detected."
Severity and Description:
Major; A memory component is suspected of causing a fault.
/SYS/MB/P[0-x]/D[0-11]
SNMP Trap:
sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message:
event fault.memory.intel.dimm.4gb-fused "An unsupported 4-gb
memory DIMM has been detected."
Severity and Description:
Informational; A memory component fault has been cleared.
/SYS/MB/P[0-x]/D[0-11]
SNMP Trap:
sunHwTrapMemoryFault
Oracle ILOM Event Message:
event fault.memory.intel.dimm.8gb-fused "An unsupported 8-gb
memory DIMM has been detected."
Severity and Description:
Major; A memory component is suspected of causing a fault.
/SYS/MB/P[0-x]/D[0-11]
SNMP Trap:
sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message:
event fault.memory.intel.dimm.8gb-fused "An unsupported 8-gb
memory DIMM has been detected."
Severity and Description:
Informational; A memory component fault has been cleared.
/SYS/MB/P[0-x]/D[0-11]
SNMP Trap:
sunHwTrapMemoryFault
/SYS/MB/P[0-x]/D[0-11]
Summary of Contents for EXADATA X6-2
Page 1: ...Part No E62171 02 June 2016 Oracle Server X6 2 Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X6 2 Service Manual June 2016 ...
Page 62: ...62 Oracle Server X6 2 Service Manual June 2016 ...
Page 226: ...226 Oracle Server X6 2 Service Manual June 2016 ...
Page 278: ...278 Oracle Server X6 2 Service Manual June 2016 ...
Page 284: ...284 Oracle Server X6 2 Service Manual June 2016 ...