4-9
Calibration
Window of Interest (WOI) Margin
Line Scan Height
Processing
Low
The reader will spend a low amount of effort attempting to decode the given symbol for
each parameter configuration.
Medium
The reader will spend a medium amount of effort attempting to decode the given symbol
for each parameter configuration.
High
The reader will spend a high amount of effort attempting to decode the given symbol for
each parameter configuration.
Definable
The processing time for each image frame is defined by
Image Processing Timeout
.
Definition:
Sets the margin size that is applied to the calibrated symbol. This parameter
is expressed in number of pixels. If the margin causes the image to exceed
the maximum image size, it will be reduced accordingly.
Serial Cmd:
<
K529,
gain,exposure,focus position,symbol type,WOI framing,
WOI
margin
, line scan height,processing
>
Default:
75 (pixels)
Options:
20 to 1280
Definition:
This parameter is only used with the Straight Line modes. It sets the scan
height of the straight-line image, and it is expressed in number of pixels.
Serial Cmd:
<
K529,
gain,exposure,focus position,symbol type,WOI framing,WOI
margin,
line scan height
,processing
>
Default:
64 (pixels)
Options:
3 to 1280
Definition:
This setting defines the amount of time and effort the reader will spend
attempting to decode a symbol for each parameter configuration.
Serial Cmd:
<
K529,
gain,exposure,focus position,symbol type,WOI framing,WOI
margin, line scan height,
processing
>
Default:
Medium
Options:
0 = Low
1 = Medium
2 = High
3 = Definable
Summary of Contents for V430-F-series
Page 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Page 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Page 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Page 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Page 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...