7-50
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Diagnostics Output 1
Diagnostics Output 1
Note: Output On
under
Output 1 Parameters
must be set to
Diagnostic Warning
for
this output to function.
Under
Output 1 Parameters
, expand the
Diagnostics
tree.
Service Unit
When
Diagnostic Warning
is enabled, the
Output On
configuration has no effect. The
output will remain active as long as one of the diagnostic warning conditions is met. The
output will become inactive once it detects that there are no diagnostic warning conditions.
Serial Cmd:
<
K790,
unused 1
,service unit
>
Default:
0
Options:
0 = Disabled
Definition:
Allows the user to set up the output to toggle to active when the service
timer has expired. This condition will only be held for one service timer
click.
Note:
This feature cannot be used if the reader is in a
Continuous Read
mode.
Serial Cmd:
<
K790,
unused 1,
service unit
>
Default:
0
Options:
0 = Disabled
1 = Enabled