7-28
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
ISO/IEC 16022 Symbol Quality Output 1
Output on Axial Non-Uniformity
Output on Unused Error Correction
Symbol Contrast Threshold
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, toggles
Output 1
to an active state when
Axial Non-Uniformity
Threshold
is met.
Serial Cmd:
<
K800,
output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,
output on axial non-uniformity
,axial non-uniformity
threshold,output on UEC,UEC threshold
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, toggles
Output 1
to an active state when
UEC Threshold
is
met.
Serial Cmd:
<
K800,
output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,
output on UEC
,UEC threshold
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Usage:
Lets the user set the acceptable level of symbol quality.
Definition:
Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D).
Serial Cmd:
<
K800,
output on symbol contrast,
symbol contrast threshold
,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,output on UEC,UEC threshold
>
Default:
Grade C
Options:
0 = Grade A
1 = Grade B
2 = Grade C
3 = Grade D
Summary of Contents for V430-F-series
Page 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Page 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Page 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Page 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Page 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...