Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
A-23
Appendices
Appendix B — Serial Commands
Serial Command Format
Microscan readers are controlled by two types of serial commands: configuration commands
and utility commands.
Rules that apply to both configuration and utility commands
• Less than ‘
<
‘
and greater than
‘
>
’ angle bracket characters enclose the commands.
• Commands and data are case sensitive. Characters must be entered as upper or lower
case, as specified.
Serial Utility Commands
Serial Utility Commands are sent during operations and are not followed by
<A>
or
<Z>
.
Serial Configuration Commands (K Commands)
Microscan’s serial configuration commands begin with a single “K”
character followed by a
3-digit numeric character, comma-separated command fields, and an initializing command,
as follows:
<
K
numeric character,data,data,...etc.
><
initializing command
>
An initializing command
<Z>
or
<A>
may follow the command.
•
<Z>
initializes the memory and saves for power-on.
•
<A>
initializes the memory but does not save for power-on.
For example, to enable
UPC
and save the change for power-on, send
<K473,
1
><Z>
.
To change
Baud Rate
and reset without saving changes for power-on, send
<K100,
3
><A>
.
Serial Configuration Command Conventions
• All command fields (except the last) must be followed by a comma (without a space).
• NULL cannot be used. The characters
<
,
>
, and
,
can be used, but only if entered as
hex values.
• All fields preceding a modified field must be included.
• If there is no change in preceding fields, then commas alone can be entered in these
fields. For example, if only the last field in the following command is changing,
<K100,
4,1,0,0
>
can be entered as
<K100
,,,,0
>
.
• All fields
following
a modified field can be omitted. For example, to change Baud Rate
only, send
<K100,
3
>
.
Concatenating Configuration Commands
Commands can be concatenated (added together) in a single string. For example,
<K145
,1
><K220,
1
><A>
enables
LRC
, sets
End of Read Cycle
mode to
New Trigger
,
and resets the data buffers without saving the changes for power-on.
Summary of Contents for V430-F-series
Page 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Page 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Page 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Page 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Page 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...