13-12
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Master Database
Enter Master Symbol Data
Usage:
Allows you to enter master symbol data for any enabled master symbol index
number (1 to 10), provided the total number of characters does not exceed
the maximum allowed.
Serial Cmd:
<
K231,
master symbol number,master symbol data
>
Options:
Enter data for 1 to 10 symbols (any combination of ASCII text up to the
maximum allowed.
For example, to enter data for master symbol 9, after making certain that
master symbol database size is enabled for 9 or more symbols, send
<K231,
9,data
>
.
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex values.
Caution:
If no data is entered, the existing data will be deleted.
ESP:
1. Open the
Utilities
menu.
2. Set the number of master symbols you want to create in
Master Symbol
Database Size
.
3. Double-click on each symbol number you want to set up and copy, or type
your data in the popup dialog and click
OK
.
4. When all your data has been entered, click the
Send Database to Reader
button.