6-28
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Pharmacode
Bar Width Status (Pharmacode)
Direction (Pharmacode)
Fixed Threshold Value (Pharmacode)
Definition:
If set to
Mixed
, the reader will autodiscriminate between narrow bars and
wide bars. If set to
All Narrow
, all bars will be considered as narrow bars. If
set to
All Wide
, all bars will be considered as wide bars. If set to
Fixed
Threshold
, it will use the fixed threshold value to determine whether the
bars are narrow or wide. The
Bar Width Status
setting will be ignored
when the reader is able to tell the difference between the narrow and the
wide bars.
Serial Cmd:
<
K477,
status,fixed symbol length status,fixed symbol length,minimum
number of bars,
bar width status
,direction,fixed threshold value,back-
ground color
>
Default:
Mixed
Options:
0 = Mixed
1 = All Narrow
2 = All Wide
3 = Fixed Threshold
Definition:
Specifies the direction in which a symbol can be read.
Serial Cmd:
<
K477,
status,fixed symbol length status,fixed symbol length,minimum
number of bars,bar width status,
direction
,fixed threshold value,back-
ground color
>
Default:
Forward
Options:
0 = Forward
1 = Reverse
Definition:
Used when
Bar Width Status
is set to
Fixed Threshold
. Defines the
minimum difference in pixels that will distinguish a narrow bar from a wide
bar.
Serial Cmd:
<
K477,
status,fixed symbol length status,fixed symbol length,minimum
number of bars,bar width status,direction,
fixed threshold value
,back-
ground color
>
Default:
10
Options:
1 to 65535
Summary of Contents for V430-F-series
Page 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Page 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Page 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Page 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Page 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...