Customer Default Parameters
Customer default parameters (saved by
<Zc>
) are the same set of parameters as power-on
parameters but are saved in a different, isolated section of NOVRAM. This allows a user
essentially to create a backup set of parameters that can be recalled in the event that the
current parameters or power-on parameters have been accidentally changed or are no
longer desired.
It is important to note that a hardware default does not affect customer default parameters.
For example, a user that has inadvertently changed communication settings and saved
them with a
<Z>
command, may not know the correct settings or have the capability to
communicate within those settings. By first doing a hardware default to restore the known
Microscan defaults, the user can then recall the previous customer saved settings with an
<Arc>
or
<Zrc>
command.
Microscan Default Parameters
Microscan default parameters are contained in the firmware and cannot be changed.
Software Defaults
Microscan default parameters can be recalled (loaded into current settings) with
<Ard>
command or recalled and saved for power-on with the
<Zrd>
command.
Hardware Default
If a software default and reset is not possible, it may be necessary to reset the reader by
shorting (connecting) specific pins. This procedure has the same effect as the
<Zrdall>
software command.
Important:
For this reset to occur, this command must be executed within 60 seconds of a
power-on or a reset.
1. Apply power to the reader.
2. Locate Pin 3 (Default) and Pin 7 (Ground) on the connector. (Access depends on wiring
configuration. May require an accessory cable).
Caution:
Be certain that the correct pins are located. Connecting the wrong pins could
cause serious damage to the unit.
3. Momentarily connect the wires (or pins).
4. Within 3 seconds, disconnect and then reconnect the two wires again.
Summary of Contents for V430-F-series
Page 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Page 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Page 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Page 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Page 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...