Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
5-7
Read Cycle
Continuous Read 1 Output
Caution:
In automated environments,
Continuous Read 1 Output
is not recommended
because there is typically no reliable way to verify that a symbol was missed.
Note:
If
Trigger Mode
is set to
Continuous Read 1 Output
, the reader will behave as if
Number of Symbols
were set to
1
, regardless of the user-defined configuration.
Usage:
Continuous Read 1 Output
can be useful in applications where it is not
feasible to use a trigger and all succeeding symbols contain different
information. It is also effective in applications where the objects are presented
by hand.
Definition:
In
Continuous Read 1 Output
the reader self-triggers whenever it
decodes a new symbol or a timeout occurs.
If
End of Read Cycle
is set to
Timeout
and the symbol doesn’t change,
the output is repeated at the end of each timeout period. For example, if
Timeout
is set to one second, the reader sends the symbol data immediately
and repeats the output at intervals of one second for as long as it continues
to capture the symbol.
If
End of Read Cycle
is set to
New Trigger
, the reader will send the current
symbol data immediately,
but only once
. A new symbol appearing in the
reader’s range will be read and sent immediately, provided it is not identical
to the previous symbol.
Serial Cmd:
<
K200,
1
>
Summary of Contents for V430-F-series
Page 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Page 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Page 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Page 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Page 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...