![background image](http://html1.mh-extra.com/html/omron/v430-f-series/v430-f-series_user-manual_741958179.webp)
7-14
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Output Indicators
Green Flash Duration
Usage:
Provides visual verification that a good read has occurred.
Definition:
When a good read occurs, the green LEDs will illuminate and stay on for
the time set in the
Green Flash Duration
value.
Serial Cmd:
<
K750,
green flash mode,target pattern status,
green flash duration
>
Default:
25
(250ms)
Options:
0 to 65535 (in 10 ms increments)
Summary of Contents for V430-F-series
Page 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Page 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Page 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Page 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Page 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...