7-26
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Trend Analysis Output 1
Trigger Evaluation Period
Number to Output On
Decodes per Trigger Threshold
Definition:
The number of triggers to examine for the trend analysis condition.
Serial Cmd:
<
K780,
trend analysis mode,
trigger evaluation period
,number to output on,
decodes per trigger threshold
>
Default:
0
Options:
0 to 255
Usage:
Example:
If
Number to Output On
is set to 3 and
Trend Analysis Mode
is
set to
No-Read
, then the output will not be activated until 3 No-Reads have
occurred.
Definition:
Sets the number of
Trend Analysis Mode
events (mismatches, No-Reads,
or reads/trigger as configured by Trend Analysis Mode) to occur within the
trigger evaluation period before activating the associated output.
Serial Cmd:
<
K780,
trend analysis mode,trigger evaluation period,
number to output on
,
decodes per trigger threshold
>
Default:
0
Options:
0 to 255
Definition:
The appropriate output will be activated if, at the end of the read cycle, the
symbol decode count is below this setting.
Note:
To activate this feature the reader must be in Decodes per Trigger
mode. To put the reader in this mode during the read cycle and the Trend
Analysis operation, the Decodes per Trigger status in the quality settings
must be enabled. Enabling this setting will also append the decode count to
the symbol data.
Serial Cmd:
<
K780,
trend analysis mode,trigger evaluation period,number to output on,
decodes per trigger threshold
>
Default:
0
Options:
0 to 65535
Summary of Contents for V430-F-series
Page 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Page 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Page 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Page 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Page 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...