Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
5-21
Read Cycle
Number of Continuous Captures
Images per Read Cycle Limit
Read Cycle History
Definition:
Specifies the number of captures to process in Continuous Capture mode.
Serial Cmd:
<
K241,
capture mode,number of captures,rapid capture mode,
number of
continuous captures
,images per read cycle limit,read cycle history
>
Default:
2
Options:
1 and 255
Definition:
Specifies the number of captures to process in a read cycle.
Serial Cmd:
<
K241,
capture mode,number of captures,rapid capture mode,number of
continuous captures,
images per read cycle limit
,read cycle history
>
Default:
10
Options:
3 and 255
Definition:
Specifies the number of images that can be stored in read cycle history.
Serial Cmd:
<
K241,
capture mode,number of captures,rapid capture mode,number of
continuous captures,
images per read cycle limit
,read cycle history
>
Default:
10
Options:
0 and 255