Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
14-5
Output Format
Format Extract
Output Index
Start Location
Length
Definition:
Output Index
refers to the database entry you wish to modify with this command.
A formatted output is built by
extracting data from a symbol’s original data
output
and/or inserting user-defined characters.
It may be helpful to think of individual indexes as positions in the final formatted
output you wish to build. Starting with index # 1, enter either an extract or
insert command to begin building your desired output string. Then, with the
next index number, enter either an extract or insert command to continue
building the output string. Continue this process until you are finished building
the string.
Serial Cmd:
<
K740,
output index
,start location,length>
Options:
1 to 100
Definition:
Defines the location within the symbol data where the character extraction will
begin. The first character extracted will also be the first character in the
sequence displayed in user-defined output.
Serial Cmd:
<
K740,
output index,
start location
,length>
Default:
0 (disabled)
Options:
0 to
n
(maximum number of characters in the symbol data).
Definition:
Defines the length (in consecutive characters) that will be extracted and
placed in user-defined output.
Serial Cmd:
<
K740,
output index,start location,
length
>
Default:
0
(disabled; end of format cell array)
Options:
0 to
n
(maximum number of characters in the symbol data).
Summary of Contents for V430-F-series
Page 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Page 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Page 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Page 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Page 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...