7-18
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Setup Button
Default on Power-On
Load Configuration Database
Save for Power-On
Definition:
When enabled, if the Setup button is held down on power-on the imager
will default to customer defaults and save for power-on. This is the same
as sending a
<Zrc>
command.
Serial Cmd:
<
K770,
global status,
default on power-on
,load Configuration Database,
save for power-on
>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
Definition:
Allows the user to load the Configuration Database with calibration results.
When the user performs a calibration using the Setup button, all the data-
base entries are moved down one index and the results of the calibration
are saved to index 1. The results will be saved as current settings as well.
Serial Cmd:
<
K770,
global status,default on power-on,
load Configuration Database
,
save for power-on
>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
Definition:
If enabled, after calibration is complete, all parameters will be saved for
power-on.
Serial Cmd:
<
K770,
global status,default on power-on,load Configuration Database,
save for power-on
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Summary of Contents for V430-F-series
Page 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Page 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Page 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Page 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Page 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...