5-6
Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
Trigger Mode and Filter Duration
Trigger Mode and Filter Duration
Trigger Mode
Continuous Read
Definition:
The
Trigger
is the event that initiates a read cycle.
Note:
When calibrating the reader or testing read rate, the current trigger
setting will be disregarded.
Serial Cmd:
<
K200,
trigger mode
,leading edge trigger filter,trailing edge trigger filter
>
Default:
Continuous Read Auto
Options:
0 = Continuous Read
1 = Continuous Read 1 Output
2 = External Level
3 = External Edge
4 = Serial Data
5 = Serial Data and Edge
6 = Continuous Read Auto
Usage:
Continuous Read
is useful in testing symbol readability or reader functions.
It is not recommended for normal operations.
Definition:
In
Continuous Read
, trigger input options are disabled, the reader is
always in the read cycle, and it will attempt to decode and transmit every
capture. If a single symbol stays within read range for multiple read cycles,
its data will be transmitted repeatedly until it leaves the read range.
The reader sends replies to serial commands that require responses when
symbol data is transmitted, or read cycle timeout is enabled and a timeout
occurs
and
at least one captured image has been processed. Depending
on the combination of enabled symbologies, the reader may take longer
than the timeout to process a captured image.
Note: When to Output
and
No-Read
options have no affect on
Continuous Read
.
Serial Cmd:
<
K200,
0
>
Summary of Contents for V430-F-series
Page 1: ...Auto Focus Multi Code Reader V430 F series User s Manual Z392 E1 02 ...
Page 9: ...CONTENTS 7 Auto Focus Multi Code Reader V430 series User s Manual Z392 ...
Page 125: ...5 28 Auto Focus Multi Code Reader V430 series User s Manual Z392 Good Decode s Needed ...
Page 279: ...9 14 Auto Focus Multi Code Reader V430 series User s Manual Z392 New Master Pin ...
Page 403: ...Omron Microscan Systems Inc 700 SW 39th St Suite 100 Renton WA 98057 USA ...