Auto Focus Multi Code Reader V430-series User’s Manual (Z392)
6-11
Symbologies
Full ASCII Set (Code 39)
Usage:
Must be enabled when reading characters outside the standard character
set (0-9, A-Z, etc.)
The user must know in advance whether or not to use the
Full ASCII Set
option. Since
Full ASCII Set
requires two code words to encode one
character, it is less efficient.
Definition:
Standard Code 39 encodes 43 characters; zero through nine, capital “A”
through capital “Z”, minus symbol, plus symbol, forward slash, space,
decimal point, dollar sign, and percent symbol. When
Full ASCII Set
is
enabled, the reader can read the full ASCII character set, from 0 to 255.
Serial Cmd:
<
K470,
status,check character status,check character output status,large
intercharacter gap,fixed symbol length status,fixed symbol length,
full ASCII
set
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled