485
Cycle Time
Section 7-3
61
INI
Built-in High-speed counter 0 or pulse output from an output bit:
1.875
81.6
Starting comparison via word
103.0
Starting comparison via
*
DM
64.9
Stopping comparison via word
74.7
Stopping comparison via
*
DM
147.3
Changing PV via word
164.0
Changing PV via
*
DM
50.8
Stopping pulse output via word
72.2
Stopping pulse output via
*
DM
High-speed counters 1 to 4 on High-speed Counter Board:
94.0
Starting comparison via word
112.0
Starting comparison via
*
DM
94.0
Stopping comparison via word
112.0
Stopping comparison via
*
DM
136.0
Changing PV via word
154.0
Changing PV via
*
DM
High-speed counters 1 and 2 or pulse output from ports 1 and 2 on Pulse I/O
Board:
267.2
Starting comparison via word
291.9
Starting comparison via
*
DM
186.6
Stopping comparison via word
209.6
Stopping comparison via
*
DM
421.5
Changing PV via word
439.1
Changing PV via
*
DM
223.9
Stopping pulse output via word
242.9
Stopping pulse output via
*
DM
High-speed counters 1 and 2 on Absolute Encoder Interface Board:
266.7
Starting comparison via word
285.1
Starting comparison via
*
DM
182.1
Stopping comparison via word
203.7
Stopping comparison via
*
DM
Code Mnemonic
ON
execution
time (
µ
s)
Conditions
OFF execution
time (
µ
s)