R and R+1 must be in the same data area. DM 6143 to DM 6655 cannot be
used for R.
Description
When the execution condition is OFF, DIV(33) is not executed and the pro-
gram moves to the next instruction. When the execution condition is ON, Dd is
divided by Dr and the result is placed in R and R + 1: the quotient in R and the
remainder in R + 1.
Flags
ER:
Dd or Dr is not in BCD.
Indirectly addressed EM/DM word is non-existent.
(Content of
*
EM/
*
DM word is not BCD, or the EM/DM area boundary
has been exceeded.)
EQ:
ON when the result is 0.
Example
When IR 00000 is ON with the following program, the content of IR 216 is
divided by the content of HR 09 and the result is placed in DM 0017 and DM
0018. Example data and calculations are shown below the program.
5-21-7 DOUBLE BCD ADD – ADDL(54)
Limitations
DM 6143 to DM 6655 cannot be used for R.