User Interface Elements
Figure 1.1 Keypad
Table 1.1 Keypad Components and Functions
Symbol
Name
Function
A
RUN LED
Illuminates to show that the drive is operating the motor.
The LED turns OFF when the drive stops.
Flashes to show that:
•
The drive is decelerating to stop.
•
The drive received a Run command with a frequency reference of 0 Hz, but the drive is not set for zero speed control.
Flashes quickly to show that:
•
The drive received a Run command from the MFDI terminals while switching from LOCAL Mode to REMOTE Mode.
•
The drive received a Run command from the MFDI terminals when the drive is not in Drive Mode.
•
The drive received a Fast Stop command.
•
The safety function shuts off the drive output.
•
The user pushed
on the keypad while the drive is operating in REMOTE Mode.
•
The drive is energized with an active Run command and
b1-17 = 1 [RUN@PowerUp Selection = Disregard RUN]
.
B
ALM LED
Illuminates when the drive detects a fault.
Flashes when the drive detects:
•
Alarm
•
Operation Errors
•
A fault or alarm during Auto-Tuning
The light turns off during regular drive operation. There are no alarms or faults.
C
microSD Card Insertion Slot The insertion point for a microSD card.
D
Function Keys
F1, F2, F3
The menu shown on the keypad sets the functions for function keys.
The name of each function is in the lower half of the display window.
E
LOCAL/REMOTE
indicator
Illuminated: The keypad controls the Run command (LOCAL Mode).
OFF: The control circuit terminal or serial transmission device controls the Run command (REMOTE Mode).
Note:
•
LOCAL: Operated using the keypad. Use the keypad to enter Run/Stop commands and the frequency reference command.
•
REMOTE: Operated from the control circuit terminal or serial transmission. Use the frequency reference source entered in
b1-01
and the Run command source selected in
b1-02
.
F
LO/RE Selection Key
Switches drive control for the Run command and frequency reference between the keypad (LOCAL) and an external source
(REMOTE).
Note:
•
The LOCAL/REMOTE Selection Key continuously stays enabled after the drive stops in Drive Mode. Set
o2-01 = 0 [LO/RE Key
Selection of Function = Disabled]
to disable switching from REMOTE to LOCAL by
.
•
The drive will not switch between LOCAL and REMOTE when it is receiving a Run command from an external source.
Summary of Contents for Q2A-A Series
Page 140: ...6 Attachments 140 TOMPYEUOQ2A03C AC Drive Q2A Installation and Operation Instructions...
Page 141: ...6 Attachments TOMPYEUOQ2A03C AC Drive Q2A Installation and Operation Instructions 141 EN...
Page 142: ...6 Attachments 142 TOMPYEUOQ2A03C AC Drive Q2A Installation and Operation Instructions...
Page 143: ...6 Attachments TOMPYEUOQ2A03C AC Drive Q2A Installation and Operation Instructions 143 EN...
Page 144: ...6 Attachments 144 TOMPYEUOQ2A03C AC Drive Q2A Installation and Operation Instructions...
Page 145: ...6 Attachments TOMPYEUOQ2A03C AC Drive Q2A Installation and Operation Instructions 145 EN...