![background image](http://html1.mh-extra.com/html/omron/k6pm-th/k6pm-th_user-manual_743374152.webp)
7 Troubleshooting
7 - 4
K6PM-TH Thermal Condition Monitoring Device User’s Manual (H231)
Transistor
output 3
Transistor out-
put 3 is OFF
A Main Unit error or
K6PM-TH sensor
error has occurred.
One of the following
Internal CPU error,
internal memory
error, K6PM-TH
sensor communica-
tions error,
K6PM-TH sensor
angle deviation
detected, tempera-
ture measurement
range exceeded,
running time error
• Turn ON the power again.
• Check the power supply to the
sensor.
• Check the communications wir-
ing with the sensor.
• Return the sensor angle to its
original state.
• Alternatively, perform position
adjustment and position regis-
tration.
• Make sure there is no error in
the measurement object.
• If it still occurs, contact our
sales or distributor.
1-9
Refer to "Transistor out-
put".
Problems
Cause
Possible correction
Reference