66
Chapter
2
Mu
ting
F3SG-R
User’s Manual
System Operation and Functions
Timing chart
Wiring diagram
Variable
Variable name
Value
Description
T
1max
Muting input time limit value
(maximum)
3 s
Maximum time difference between muting inputs A and B.
If the time difference between muting inputs A and B is larger
than this value, a muting error occurs.
T
2
Muting time limit
60 s
The duration time of the Muting function. The Muting state is
cancelled if it continues for longer than this time limit.
T
3
Maximum allowable muting
signal interruption
0.1 s
Maximum duration of a signal interruption allowed in muting
inputs A and B.
Muting input A
(Limit switch1)
ON
OFF
Muting input B
(Limit switch2)
Beam state
Unblocked
Blocked
OSSD
ON
OFF
ON
OFF
Enabled
Disabled
T1max
Muting state
T2 max.
T2 max.
80 ms max.
T3 (0.1 s) max.
T3 (0.1 s) max.
S1
S1
㻿㻞
㻿㻞
MUTE A : Gray
MUTE B : Pink
MUTE A : Gray
MUTE B : Pink
S1, S2: Muting sensor
F39-JG
A-D
F39-JG
A-D
S1, S2: Muting sensor
PNP output
NPN output
Receiver
Receiver
Power supply
0 VDC : Blue
0 VDC : Blue
24 VDC : Brown
24 VDC : Brown
0 VDC
+24 VDC
Power supply
0 VDC
+24 VDC
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Page 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Page 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Page 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...