Installation example 1 of standard muting mode (Using two muting sensors)
This is an example of two retro-reflective type photoelectric sensors used as muting sensors installed
in a cross pattern.
Use two sensors when the length L of the workpieces are not constant or are insufficient.
1.
Before a workpiece passes through
The output state of muting sensors A1 and B1 are both OFF, and the safety function of the F3SG-RA is
working.
In this example where two muting sensors are used, the crossover point of muting sensors A1 and B1
is in the hazardous zone. This configuration prevents the muting function from being enabled by a
person passing through the crossover point.
2.
Muting state started
When muting sensors A1 and B1 are turned ON in this order, the F3SG-R enters the muting state. In
this state, the safety function of F3SG-RA is disabled.
Workpiece
L
F3SG-RA
F3SG-RA
d1=D1
B1
Reflector
Reflector
A1
Hazardous zone
V
The crossover point of muting sensors
A1 and B1 must be located within the
hazardous zone
L: Length of workpiece
d1: Maximum distance required for the muting sensor to keep the muting function enabled
D1: Minimum distance required for the muting sensor to keep the muting function enabled
Workpiece
F3SG-RA
Hazardous zone
B1
Reflector
Reflector
A1
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Page 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Page 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Page 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...