74
Chapter
2
Over
rid
e
F3SG-R
User’s Manual
System Operation and Functions
Factory default setting
Wiring diagram
When External Device Monitoring Enabled
Variable
Variable name
Value
Description
T1
Override input time limit
1 s
Maximum input time of override input.
T2
Override time limit
600 s
The duration time of the Override function. The Override state is
cancelled if it continues for longer than this time limit.
*1. Also used as Override input line.
*2. Make sure to connect an override cancel switch to
the Reset line when using the override function.
Otherwise the override state may not be released
by the override cancel switch, resulting in serious injury.
F39-JG
A-D
F39-JG
A-D
S1: Lockout/Interlock Reset Switch or Override Switch
S2: Override Cancel Switch
S3, S4: Muting sensor
KM1, KM2: External device feedback
RESET : Yellow *1
S1
S2
*2
*2
S3
S4
KM1
KM2
S1
S2
S3
S4
KM1
KM2
MUTE A : Gray
MUTE B : Pink
PNP output
NPN output
Receiver
Receiver
Power supply
0 VDC : Blue
24 VDC : Brown
RESET : Yellow *1
MUTE A : Gray
MUTE B : Pink
0 VDC : Blue
24 VDC : Brown
0 VDC
+24 VDC
Power supply
0 VDC
+24 VDC
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Page 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Page 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Page 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...