![Omron F3SG-RA User Manual Download Page 168](http://html1.mh-extra.com/html/omron/f3sg-ra/f3sg-ra_user-manual_743106168.webp)
144
Chapter
4
Dimens
io
ns
F3SG-R
User’s Manual
Wiring/Installation
4-3-3. Mounted with Top/Bottom Adjustable Brackets (F39-LGTB)
and Standard Adjustable Brackets (F39-LGA)
4-3-3-1. F3SG-RA Series
F3SG-RA Series Except F3SG-4RA0190-30 and F3SG-4RA0160-14
[Backside Mounting]
4-4-3-3. Mounting with Top/Bottom Adjustable Brackets (F39-LGTB)
- Use the brackets of specified quantities and locations according to the dimensions. The other brackets than described above may not meet the specified ratings and performance.
- When you use the sensor in a situation where the sensor is under a load, increase the number of the brackets used.
- The Top/Bottom Adjustable Bracket and Standard Adjustable Bracket allow beam alignment after fixing the bracket to a wall surface. The angle
adjustment range of the Top/Bottom Adjustable Brackets is ±22.5°. The angle adjustment range of the Standard Adjustable Brackets is ±15°.
<Screw for Top/Bottom Adjustable
Bracket: M5 or M6>
<Screw for Top/Bottom Adjustable
Bracket: M8>
Standard Adjustable
Bracket
(F39-LGA)
Top/Bottom
Adjustable Bracket
(F39-LGTB)
Top/Bottom
Adjustable Bracket
(F39-LGTB)
Backside : 2-S3
2-M5 or M6
2-M5 or M6
2-M5 or M6
C1 (Protective height for 30 mm)
C2 (Protective height for 14 mm)
2-M8
S2.5
12
35
40.8
G
H
I
26.5
35
23.2
8.2
A
9.2
72
6.4
84
6.5
4
2-S3
53.25
48.6
35
13.6
4
4
18
33
43
D
P
F
F
25.75
24.85
46.5
H
38.5
G
33.75
24.85
72
24.85
72
[ Unit : mm ]
F3SG-
RA
-30 Series
Optional
accessory not
connected
Optional accessory connected*
F39-JGR2W
F39-BT
F39-LP
F39-BTLP
Dimension A
C1+18
Same as on the left
Dimension C1
4-digit number of the type
name (Protective height)
Same as on the left
Dimension D
C1-50
Same as on the left
Dimension G
C1+77.5
C1+80.5
C1+91
C1+102.5
Dimension H
C1+103
C1+106
C1+116.5
C1+128
Dimension I
C1+122
C1+125
C1+135.5
C1+147
Dimension P
20
Same as on the left
Protective height
(C1)
Number of Top/Bottom
Adjustable Brackets*1
Number of Standard
Adjustable Brackets *1 *2
Dimension F
0270 to 1070
2
0
-
1150 to 1950
2
1
1000 mm max.
2030 to 2510
2
2
1000 mm max.
F3SG-
RA
-14 Series
Optional
accessory not
connected
Optional accessory connected*
F39-JGR2W
F39-BT
F39-LP
F39-BTLP
Dimension A
C2+48
Same as on the left
Dimension C2
4-digit number of the type
name (Protective height)
Same as on the left
Dimension D
C2-20
Same as on the left
Dimension G
C2+107.5
C2+110.5
C2+121
C2+132.5
Dimension H
C2+133
C2+136
C2+146.5
C2+158
Dimension I
C2+152
C2+155
C2+165.5
C2+177
Dimension P
10
Same as on the left
Protective height
(C2)
Number of Top/Bottom
Adjustable Brackets*1
Number of Standard
Adjustable Brackets *1 *2
Dimension F
0240 to 1040
2
0
-
1120 to 1920
2
1
1000 mm max.
2000 to 2080
2
2
1000 mm max.
*1. The number of brackets required to mount either one of emitter and receiver.
*2. The Top/Bottom Adjustable Bracket is not useable together with the Standard Fixed Bracket. When it is necessary to use it with another bracket, only
the combination with the Standard Adjustable Bracket is possible.
Connected with Optional Accessories
for more information on the dimensions when optional accessories are connected to the F3SG-RA.
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Page 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Page 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Page 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...