76
Chapter
2
Over
rid
e
F3SG-R
User’s Manual
System Operation and Functions
Timing chart
2-13-3. Setting with DIP Switch
The user cannot make any changes to this function by the DIP Switch.
2-13-4. Setting with Configuration Tool
Some settings of functions configurable with the Configuration Tool may increase risks.
Make sure the Responsible Person conduct a thorough risk assessment analysis before
managing and changing the settings. Unintended changes to the settings may cause a
person to go undetected, resulting in serious injury.
The user can make changes to the settings by the Configuration Tool.
Make sure the Position 8 of the DIP Switch is set to Configuration Tool Enabled to activate the settings by the
Configuration Tool.
Setting the override time limit to infinite may cause a failure of disabling the override state when there is a failure of the
override input signal. Conduct risk assessment analysis thoroughly before enabling this setting.
Refer to
Safety Light Curtain Configuration Tool for Model F3SG (SD Manager 2) User’s Manual
for more
information on setting this function by the Configuration Tool.
Function name
Factory Default Setting
Available Parameters
Override
Enable
Enable/Disable
Override input time limit
1 s
0.1 to 5 s in 0.1-s increments
Override time limit
600 s
1 to 600 s in 1-s increments, or infinite
Reset Input
ON
OFF
Override State
Beam state
Unblocked
Blocked
Enabled
Disabled
OSSD
ON
OFF
T1 T1
T1 T1 T1
T1
ON
OFF
Power
2 to 5 s
1 s max.
1 s max.
T2 max.
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Page 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Page 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Page 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...