99
F3SG-R
User’s Manual
Chapter
2
La
mp
System Operation and Functions
E
The user can make changes to the settings by the Configuration Tool.
*1. Setting parameters of this function can be saved according to the states where the Muting function
is enabled and disabled, respectively. After changing the Muting function from Enable to Disable or
from Disable to Enable, also check the settings of this function again.
Considerations for enabling and disabling Muting function
for more information on settings of the Muting function.
*2. Refer to the table of Information (Output operation mode) assigned to Lamp below.
*3. The Lamp illuminates according to the patterns as shown in the output pattern chart below.
Output pattern chart
Information (Output operation mode) assigned to Lamp
Lamp output
Function
Factory Default Setting
Available Parameters
Muting function *1
Enabled
Disabled
Red
(Priority 1)
Output operation mode
Safety output information
Safety output information *2
Inverted signal output
Enable
Enable
Enable/Disable
Output pattern
Solid-ON
Solid-ON
Solid-ON/ON 1 time/ON 2
times/ON 3 times *3
Orange
(Priority 2)
Output operation mode
Stable-state information
Stable-state information
*2
Inverted signal output
Enable
Enable
Enable/Disable
Output pattern
ON 1 time
ON 1 time
Solid-ON/ON 1 time/ON 2
times/ON 3 times *3
Green
(Priority 3)
Output operation mode
Safety output information
Safety output information *2
Inverted signal output
Disable
Disable
Enable/Disable
Output pattern
Solid-ON
Solid-ON
Solid-ON/ON 1 time/ON 2
times/ON 3 times *3
Information Name
Description
(Auxiliary output is turned ON under the following condition)
Safety output information
When Safety output is in the ON state
Interlock information
Under Interlock state
Lockout information
Under error/ Lockout state
Excess power-on time
information
When power-on time exceeds power-on time threshold
Excess load switching
frequency information
When load switching frequency exceeds load switching frequency threshold
Stable-state information
When the F3SG-R is unblocked with stable light intensity
Muting information
Under Muting state
Override information
Under Override state
Muting/Override information
Under either Muting or Override state
Solid-ON
ON 3 times
ON 2 times
ON 1 time
1 s
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Page 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Page 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Page 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...