54
Chapter
2
Mu
ting
F3SG-R
User’s Manual
System Operation and Functions
This distance must prevent the muting state from being enabled by a person passing through the
muting sensors.
Also, install the F3SG-R and muting sensors so that each workpiece passes through all muting
sensors before the next workpiece arrives at the first muting sensor (PNP mode).
<Wiring diagram (PNP setting)>
<Timing chart>
B1
A1
+ 24 VDC
0 V
Power
supply
Muting Input B: Pink
Muting Input A: Gray
Muting Input B: Pink
Muting Input A
:
Gray
Reflector
Reflector
A1
B1
F3SG-RA
Using a photoelectric switch as a muting sensor
Note. Two-wire type muting sensor cannot be used.
Using an N.O contact type switch as a muting sensor
A1, B1: Retro-reflective
photoelectric switch
- PNP Output
- Dark-ON
A1, B1: N.O. contact type switch
Muting sensor A1
ON
OFF
Muting sensor B1
Unblocked
Blocked
OSSD
ON
OFF
ON
OFF
Muting state
Enabled
Disabled
T2 max.
Beam state
T3 max.
T3 max.
T1min to T1max
80 ms max.
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Page 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Page 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Page 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...