156
Chapter
4
M
ount
in
g
F3SG-R
User’s Manual
Wiring/Installation
4-4-3. Mounting Procedure
Before mounting (in case of F3SG-RA)
When it is required to configure functions with DIP Switch, do so before installing the F3SG-RA in your
site, according to the procedure described in
.
The mounting procedure is the same between F3SG-RA and F3SG-RE series.
4-4-3-1. Mounting with Standard Fixed Brackets (F39-LGF)
1.
Loosen the hexagon socket head cap screws (M3 x 15). (Fig.1)
2.
Slide the hook of the Fixed Bracket (1) in the groove of the F3SG-R housing. Lightly tighten the
hexagon socket head cap screw (M3 x 15). (Fig. 2)
3.
Adjust the Standard Fixed Bracket to the mounting position of the wall surface. Securely tighten the
hexagon socket head cap screw (M3 x 15) to fix the Standard Fixed Bracket to the housing of the
F3SG-R. The recommended torque to tighten the hexagon socket head cap screw (M3 x 15) is 2.0
N•m. (Fig. 3)
Tightening screws with a torque that considerably exceeds the recommended torque may cause failure.
hook
Fig. 1
Loosen this
Hexagon socket head
cap screw (M3 x 15)
Fixed Bracket
<Backside mounting>
<Side mounting>
Optical surface
of F3SG-R
Optical surface
of F3SG-R
Lightly
tighten this
Fixed Bracket
Fixed Bracket
Slide the hook
in the groove
Lightly
tighten this
Fig. 2
Slide the hook
in the groove
<Backside mounting>
<Side mounting>
Securely
tighten this
Adjust the bracket
to mounting position
Securely
tighten this
Adjust the bracket
to mounting position
Fig. 3
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Page 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Page 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Page 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...