79
F3SG-R
User’s Manual
Chapter
2
Fixe
d Bla
n
king
System Operation and Functions
E
For detection capability on the border between the blanking zone and normal detection zone when
allowable beam is configured, see next table.
F3SG-R LED indicator status
When fixed blanking is being enabled, the blanking indicator turns on.
Constraint between Fixed Blanking Zones
More than one fixed blanking zone can be configured adjacently (Figures 1 and 2). But allowable
beams cannot be set adjacently (Figure 3). You cannot overlap fixed blanking zones. (Figure 4)
Limitation for Combination with Other Functions
You can use this function in combination with muting, floating blanking, and warning zone functions at
the same time with the setting tool for F3SG-R.
Allowable Beam on One End
F3SG-
RA
-14
F3SG-
RA
-30
Disable
14 (same as nominal)
30 (same as nominal)
1 beam
24
50
2 beams
34
-
n beams
14+(10×n)
30+(20×n)
Detection capability on the border between the blanking zone
and normal detection zone when allowable beam is specified.
[mm]
Normal detecting beam
Fixed blanking beam
Allowable beam
Figure 4
Figure 3
Figure 1
Figure 2
Fixed blanking zone 1
Fixed blanking zone 2
Fixed blanking zone 1
Fixed blanking zone 2
Fixed blanking zone 1
(Allowable beam: 1 lower beam)
Fixed blanking zone 1
(Lower 1 allowable beam)
Fixed blanking zone 2
(Upper 1 allowable beam)
Fixed blanking zone 2
Upper
Upper
Upper
Upper
Lower
Lower
Lower
Lower
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Page 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Page 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Page 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...