The user can make changes to the settings by the Configuration Tool.
2-24-5. Load Switching Frequency
The user can view the number of operations of the load connected to F3SG-RA. The number of load
operations can be used to understand the switching frequency of relays and contactors connected to
F3SG-RA.
It is possible to give an output signal to the auxiliary output or indicate with Lamp (F39-LP and F39-
BTLP, sold separately) when the number of operations exceeds the switching frequency threshold.
The excess load switching frequency information must be assigned to the output operation mode of
the auxiliary output or Lamp.
The user can make changes to the settings by the Configuration Tool.
2-24-6. Muting Statistics Information
This function logs and visualizes conditions of F3SG-RA muting operations to help the user adjust
settings of muting input time difference. Also, its statistic calculation allows for optimal settings with
reduced test runs.
Refer to
Safety Light Curtain Configuration Tool for Model F3SG (SD Manager 2) User’s Manual
for more
information on setting this function by the Configuration Tool.
Function
Factory Default Setting
Available Parameters
Power-on time threshold
30,000 h
30,000 to 1,000,000 h in 1-h increments/Disable
Function
Factory Default Setting
Available Parameters
Load switching frequency threhshold
100,000 times in 1-time increment 100,000 to 4,000,000 times in 1-time increments/
Disable
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Page 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Page 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Page 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...