Appendix
Interlock reset
Cancels the Interlock state.
Inverted signal output mode
In this mode, the logic of the Auxiliary output signal is reversed.
L
Light level diagnosis information
Information to be signaled to the Auxiliary output or Lamp when the Safety
output is in the ON state and when the incident light level is from 100% to 170%
of the ON-threshold value for 10 seconds or more. To signal the information,
the Light Level Diagnosis information must be assigned to an output
destination.
Light level monitoring
Function to read out the light level of incident light or ambient light on the
F3SG-RA.
Load switching frequency
Function to display the number of operations of a load to be connected to the
F3SG-RA. The number is counted from when the number was last reset until
the present time.
Lockout
Function to keep the Safety outputs in the OFF state when an error is detected
by the F3SG-R.
Lockout information
Information to be signaled to the Auxiliary output or Lamp when an error or
lockout occurs. To signal the information, the Lockout information must be
assigned to an output destination.
Lower beam(s)
Beams located toward the Power Cable of the F3SG-R.
M
Maintenance information
Function to read the maintenance information of the F3SG-RA and view it on a
PC screen, with the Configuration Tool.
Manual reset mode
Function to enable the Start Interlock and Restart Interlock. The Safety outputs
are turned ON by applying a reset signal when there is no object in the
detection zone.
Maximum allowable muting signal interruption
Maximum duration of a signal interruption allowed in Muting inputs A and B.
Muting
Function to temporarily disable the safety function of the F3SG-RA and keep
the Safety outputs in the ON state even if the F3SG-RA is blocked.
Muting end wait time
Time difference from when the F3SG-RA is unblocked until the Muting state is
cancelled.
Muting input time limit value (maximum)
Maximum time difference between Muting inputs A and B.
Muting input time limit value (minimum)
Minimum time difference between Muting inputs A and B.
Muting key cap
Connector to be attached to the end cap of an emitter or receiver to use the
Muting function.
Muting sensor
Input device, such as photoelectric sensor or proximity sensor, to give an input
signal for notifying the start and end of the Muting function.
Muting sequence error
An error that occurs when muting signal is not received in the correct order. The
Safety outputs keep in the ON state unless the F3SG-RA is blocked.
Muting time limit
The duration time of the Muting function. The Muting state is cancelled if it
continues for longer than this time limit.
N
Number of floating beams
Number of beams to be configured in the Floating Blanking zone, for which the
F3SG-RA does not transition to the Lockout state or Machine Stop state (Safety
output OFF) even when blocked.
O
Object resolution (Detection capability)
Minimum size of an object that can be detected in the protective height of the
F3SG-R.
Operating range selection
Function to change the operating range by changing the emission light level of
the F3SG-R.
Operating status monitoring
Function to read out the I/O data and status of functions of the F3SG-RA.
Output operation mode
Information to be signaled to an output part (Safety output, Auxiliary output).
Override
Function that forcibly turns the Safety outputs ON when the Muting is not
working.
Override input time limit (maximum)
Input time limit (maximum value) of the special sequence to activate the
Override function.
Override time limit
The duration time of the Override function. The Override state is cancelled if it
continues for longer than this time limit.
Term
Description
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...