![Omron F3SG-RA User Manual Download Page 85](http://html1.mh-extra.com/html/omron/f3sg-ra/f3sg-ra_user-manual_743106085.webp)
61
F3SG-R
User’s Manual
Chapter
2
Mu
ting
System Operation and Functions
E
Wiring diagram
Installation Example of Exit-Only Muting Mode
This is an installation example of exit-only muting mode. When exit-only muting mode is set, install the
muting sensor on the hazardous side of the workpiece exit.
This can be used if a workpiece has a certain length and the hazardous side of the workpiece exit has
enough space around it.
1.
Before a workpiece passes through
All muting sensors are turned OFF and the safety function of the F3SG-RA is working.
MUTE A : Gray
MUTE B : Pink
MUTE A : Gray
MUTE B : Pink
S1
S2
S1
S2
S1, S2:
Muting sensor
F39-JG
A-D
F39-JG
A-D
S1, S2:
Muting sensor
PNP output
NPN output
Receiver
Receiver
Power supply
0 VDC : Blue
24 VDC : Brown
0 VDC : Blue
24 VDC : Brown
0 VDC
+24 VDC
Power supply
0 VDC
+24 VDC
Workpiece
F3SG-RA
A1 B1
Hazardous zone
A1 : Muting sensor to be connected
to muting input A
B1 : Muting sensor to be connected
to muting input B
V
d2
d1
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Page 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Page 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Page 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...