8
Chapter
1
List of
Fea
ture
s
F3SG-R
User’s Manual
Overview and Specifications
Functions by F3SG-RA software versions
Note: F3SG-RA of serial number D
□□□□
216 and later have different factory default settings from
the older ones, as shown in the below table.*1
*1. The serial number indicates the following meanings.
Refer to
Safety Light Curtain Configuration Tool for Model F3SG (SD Manager 2) User’s Manual
for more
information on differences of the functions by Configuration Tool versions.
Difference in F3SG-RA factory default settings
Refer to
to check versions of your F3SG-R.
Function
F3SG-RA Software Version
Version 1.0
Version 1.1 and up
Floating Blanking
Temporarily Disable Monitoring function is only
available when the F3SG-RA is in one
segment system.
Temporarily Disable Monitoring function is
available when the F3SG-RA is in either one
segment system or cascade connection.
Muting Statistics Information
All functions available except Online
monitoring and Clearing muting statistic logs.
All functions available including Online
monitoring and Clearing muting statistic logs.
Output
Muting
Function
Factory Default Setting
Before D
□□□□
216
D
□□□□
216 and later
Auxiliary Output
Enabled
Output operation mode
Muting/Override information
Safety output information
Inverted signal output
Disable
Enable
Output pattern
ON 1 time
Solid-ON
Disabled
Output operation mode
Safety output information
Safety output information
Inverted signal output
Enable
Enable
Output pattern
Solid-ON
Solid-ON
Lamp
(red)
Enabled
Output operation mode
None
Safety output information
Inverted signal output
Disable
Enable
Output pattern
Solid-ON
Solid-ON
Disabled
Output operation mode
None
Safety output information
Inverted signal output
Disable
Enable
Output pattern
Solid-ON
Solid-ON
Lamp
(orange)
Enabled
Output operation mode
None
Stable-state information
Inverted signal output
Disable
Enable
Output pattern
Solid-ON
ON 1 time
Disabled
Output operation mode
None
Stable-state information
Inverted signal output
Disable
Enable
Output pattern
Solid-ON
ON 1 time
Lamp
(green)
Enabled
Output operation mode
Muting/Override information
Safety output information
Inverted signal output
Disable
Disable
Output pattern
ON 1 time
Solid-ON
Disabled
Output operation mode
None
Safety output information
Inverted signal output
Disable
Disable
Output pattern
Solid-ON
Solid-ON
D 0000 2 16
Year of manufacture (last two digits)
Month of manufacture (January to September, X: October, Y: November, Z: December)
Serial number (4 digits) This number is reset at the start of each month.
L: emitter, D: receiver
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Page 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Page 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Page 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...