E
To enable the muting state, D3 and d2 must satisfy formulas (3) and (4), respectively.
This distance must prevent the muting state from being enabled by a person passing through the
muting sensors. Also, install the F3SG-RA and muting sensors so that each workpiece passes through
all muting sensors before the next workpiece arrives at the first muting sensor.
<Wiring diagram (PNP setting)>
Moving direction
Workpiece
Workpiece
Workpiece
Workpiece
Moving direction
+ 24 VDC
0 V
Power
supply
A2
A1 B2
B1
Muting input A: Gray
B2
A1 A2
B1
F3SG-R
Using a photoelectric switch as a muting sensor
Note. Two-wire type muting sensor cannot be used.
Using an N.O. contact type switch as a muting sensor (PNP mode)
A1, B1, A2, B2 :
Through-beam type
photoelectric switch
- PNP Output
- Dark-ON
A1, A2, B1, B2:
N.O. contact type switch
Muting input B: Pink
Muting input A: Gray
Muting input B: Pink