Chapter 5
5-6
Specifications
■
External Dimensions
5-2-4 Braking Resistor Unit
■
3G3IV-PLKEB20P7
The Braking Resistor Unit uses a resistor to absorb regenerative energy of the motor to reduce deceleration
time. (Usage rate: 10% ED.)
Note
“Usage rate: 10% ED” indicates that 10% of the operating time of one cycle can be used for
braking (deceleration time).
■
Applicable Models
Note
The “max. number per Inverter” indicates the maximum number of Braking Resister Units that
can be connected per Inverter.
Inverter
Braking Resistor Unit
Voltage class
Max. applicable
motor capacity
(kW)
Model
Resistor
specifications
Unit (See note.)
Number of
parts
Max.
number per
Inverter
200 V
0.2
3G3IV-PLKEB20P7
70 W, 200
Ω
1
1
0.4
(Unit: mm)