Chapter 4
4-13
Maintenance Operations
■
Replacing the Cooling Fan
If a cooling fan fault (E07) is displayed, or if the cooling fan needs replacement, take the following
steps to replace it.
1.Remove the fan cover mounting screws.
2.Insert a flat-blade screwdriver into the slot (indicated by “A”), and pull off the fan cover in the di-
rection indicated by “1.”
3.Remove the fan and pull out the fan connector (in the direction indicated by “2”) from the socket
on the board side in the case. Do not pull on the wires alone. Doing so may break the wires.
4.Insert the connector for the new fan into the socket on the board side in the case.
Position the connector so that the connector latches are aligned.
5.Secure the fan in the case.
Check that the wiring direction is as shown in Fig. 2, and mount the fan with the seal facing out-
wards.
6.Replace the fan cover and tighten the mounting screws.
The cooling fan replacement is now complete.
●
Replacement Cooling Fan Model (for 3G3JE)
For details on cooling fan models, refer to
5-2 Option Specifications
.
1
Fan cover mounting screw
Fig. 1
A
2
Fig. 2
Fan connector
Keep the fan seal to the outside.
Summary of Contents for EasySpeed 3G3JE
Page 1: ...3G3JE Compact Simplified Inverters Cat No I547 E1 02 USER S MANUAL...
Page 3: ...USER S MANUAL 3G3JE Compact Simplified Inverters...
Page 18: ...Table of Contents XVI...
Page 19: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature...
Page 23: ...Chapter 2 Design 2 1 Installation 2 2 Wiring...
Page 86: ...Chapter 3 3 26 Operation...
Page 100: ...Chapter 4 4 14 Maintenance Operations...
Page 101: ...Chapter 5 Specifications 5 1 Inverter Specifications 5 2 Option Specifications...
Page 112: ...Chapter 5 5 12 Specifications...
Page 113: ...Chapter 6 Parameter Tables...
Page 118: ...Chapter 6 6 6 Parameter Tables...
Page 130: ...Chapter 7 7 12 Appendix...
Page 132: ...R 2 Revision History...