Chapter 4
4-6
Maintenance Operations
e01
Memory fault
A fault was detected in
the Inverter's internal
memory.
Internal circuit fault
If the fault persists even after
the power has been turned
OFF and back ON, then
replace the Inverter.
t5t
EEPROM write error
A power interruption occurred during
an overload.
Turn the Inverter power OFF
and back ON. (The immedi-
ately preceding accumulated
operating time is not added.)
Not lit
Power supply fault,
power supply under-
voltage, control
power supply fault,
or hardware error
No power supply is provided.
Check and correct the power
supply wire and voltage.
Terminal screws are loosened.
Check and tighten the termi-
nal screws.
The Inverter is damaged.
Replace the Inverter.
Fault
display
Fault name and
meaning
Probable cause
Correction