Chapter 3
3-8
Operation
■
Stopping the Motor
• When finished operating the motor in the no-load state, press the STOP/RESET Key. The motor will
stop.
After checking the operation with the motor in no-load status, connect the mechanical system and
operate with an actual load using the Digital Panel keys.
• Confirm that the motor has stopped completely before connecting the mechanical system.
• Be sure to tighten all the screws when connecting the motor axis to the mechanical system.
• If an error occurs during operation, immediately press the STOP/RESET Key on the Digital Opera-
tor.
• First set the frequency reference to a low speed of one tenth the normal operating speed. (Set the
frequency reference somewhat lower than the actual operating speed.)
■
Checking the Operating Status
• Check that the operating direction is correct and that the machine is operating smoothly at slow
speed before increasing the frequency reference.
• After changing the frequency reference or the rotation direction, check that there is no vibration or
abnormal sound from the motor. Check the monitor display to confirm that the output current is not
becoming excessive.
• Refer to
3-4-4 Selecting Forward or Reverse Operation
for information on forward/reverse operation
selection. If parameter initialization (P20) is performed, reverse operation will be prohibited (P13).
To change the direction of rotation for actual load operation, enable reverse operation (P13). Refer
to
3-6-9 Selecting Reverse Rotation Prohibition
for information on the reverse rotation prohibit
selection (P13).
Key sequence
Indicator
Display example
Explanation
@
RUN
Goes out.
Press the STOP/RESET Key to stop the motor.
The
@
RUN indicator will go out and the motor
will stop.
6
Actual Load Operation
STOP
RESET
20.0
Summary of Contents for EasySpeed 3G3JE
Page 1: ...3G3JE Compact Simplified Inverters Cat No I547 E1 02 USER S MANUAL...
Page 3: ...USER S MANUAL 3G3JE Compact Simplified Inverters...
Page 18: ...Table of Contents XVI...
Page 19: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature...
Page 23: ...Chapter 2 Design 2 1 Installation 2 2 Wiring...
Page 86: ...Chapter 3 3 26 Operation...
Page 100: ...Chapter 4 4 14 Maintenance Operations...
Page 101: ...Chapter 5 Specifications 5 1 Inverter Specifications 5 2 Option Specifications...
Page 112: ...Chapter 5 5 12 Specifications...
Page 113: ...Chapter 6 Parameter Tables...
Page 118: ...Chapter 6 6 6 Parameter Tables...
Page 130: ...Chapter 7 7 12 Appendix...
Page 132: ...R 2 Revision History...