Chapter 3
3-24
Operation
●
Setting the Communications Unit Number
Sets the Communications unit number
.
●
Setting the Communications Baud Rate
Sets the communications baud rate.
●
Setting the Communications Data Length
Sets the communications data length.
●
Setting the Communications Stop Bits
Sets the number of communications stop bits.
P15
Communications unit number
Changes during
operation
No
Setting range
0 to 99
Default setting
1
P16
Communications baud rate
Changes during
operation
No
Setting range
2.4/4.8/9.6/19.2 (kbps)
Default setting
9.6
Selected item
Description
24 (
24
)
2.4 kbps
48 (
48
)
4.8 kbps
96 (
96
)
9.6 kbps
192 (
192
)
19.2 kbps
P17
Communications data length
Changes during
operation
No
Setting range
7/8 (bits)
Default setting
7
Selected item
Description
7 (
7
)
7 bits
8 (
8
)
8 bits
P18
Communications stop bits
Changes during
operation
No
Setting range
1/2 (bits)
Default setting
2
Selected item
Description
1 (
1
)
1 bit
2 (
2
)
2 bits
Summary of Contents for EasySpeed 3G3JE
Page 1: ...3G3JE Compact Simplified Inverters Cat No I547 E1 02 USER S MANUAL...
Page 3: ...USER S MANUAL 3G3JE Compact Simplified Inverters...
Page 18: ...Table of Contents XVI...
Page 19: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature...
Page 23: ...Chapter 2 Design 2 1 Installation 2 2 Wiring...
Page 86: ...Chapter 3 3 26 Operation...
Page 100: ...Chapter 4 4 14 Maintenance Operations...
Page 101: ...Chapter 5 Specifications 5 1 Inverter Specifications 5 2 Option Specifications...
Page 112: ...Chapter 5 5 12 Specifications...
Page 113: ...Chapter 6 Parameter Tables...
Page 118: ...Chapter 6 6 6 Parameter Tables...
Page 130: ...Chapter 7 7 12 Appendix...
Page 132: ...R 2 Revision History...