Chapter 4
4-3
Maintenance Operations
4-1
Protective and Diagnostic Functions
This section describes the fault information output for Inverter protection, motor burning protection,
and Inverter internal circuit protection. If a fault occurs, refer to
Fault Displays and Corrective Mea-
sures
on page 4-4 and take suitable corrective measures.
■
Inverter Faults
• If a fault occurs, the Inverter will display a fault message on the Digital Operator.
• The fault contact output will operate and the Inverter output will be turned OFF, causing the motor to
coast to a stop.
Note
The stopping method can be selected for some faults.
• Inverter output will not be interrupted for an accumulated operating time fault.
■
Clearing Faults
Faults can be cleared using any of the following methods.
• Turn the power supply OFF and back ON again.
• If the PLC has been selected for the operation command selection (P10), turn STF ON and then
OFF again.
• If key operations have been selected for the operation command selection (P10), press the STOP/
RESET Key on the Digital Operator.
• Execute the STOP/RESET operation command with a communications command. (This can be
done with Communications Models only.)
Summary of Contents for EasySpeed 3G3JE
Page 1: ...3G3JE Compact Simplified Inverters Cat No I547 E1 02 USER S MANUAL...
Page 3: ...USER S MANUAL 3G3JE Compact Simplified Inverters...
Page 18: ...Table of Contents XVI...
Page 19: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature...
Page 23: ...Chapter 2 Design 2 1 Installation 2 2 Wiring...
Page 86: ...Chapter 3 3 26 Operation...
Page 100: ...Chapter 4 4 14 Maintenance Operations...
Page 101: ...Chapter 5 Specifications 5 1 Inverter Specifications 5 2 Option Specifications...
Page 112: ...Chapter 5 5 12 Specifications...
Page 113: ...Chapter 6 Parameter Tables...
Page 118: ...Chapter 6 6 6 Parameter Tables...
Page 130: ...Chapter 7 7 12 Appendix...
Page 132: ...R 2 Revision History...