Chapter 6
6-5
Parameter Tables
• Set values for P06, P07, and P08 are changed in increments of 0.1 up to 99.9. From 100 and up
they are changed in increments of 1.0.
• P15 to P19 are not displayed for Standard Models. Refer to the
Communications Manual
for details.
• P11 is not displayed for Communications Models.
P12
Multi-function output
selection
Used to select the function of the
multi-function output terminal.
0: Not allocated.
1: Zero speed (Output turned ON
when the output frequency is 0 Hz
or operation is stopped.)
2: Frequency matching (Output
turned ON when the output fre-
quency and the frequency refer-
ence are the same.)
3: Reverse operation (Output turned
ON when the direction of rotation
is set for reverse operation.)
0 (
0
)
1 (
1
)
2 (
2
)
3 (
3
)
0
None
3-21
P13
Reverse rotation prohibit
selection
Used to select the operation for when
a reverse rotation command is input.
F.R:
Forward or reverse rotation
FWD: Forward rotation only (Reverse
rotation prohibited.)
F.R (
f.r
)
FWD (
fwd
)
FWD
None
3-22
P14
Carrier frequency selec-
tion
Used to set the carrier frequency.
4K: 4 kHz
7K: 7 kHz
4k (
4k
)
7k (
7k
)
4K
Hz
3-22
P15
Communications unit
number
Used to set the communications unit
number.
0 to 99
1
None
3-24
P16
Communications baud
rate
Used to set the baud rate.
24: 2.4 kbps
48: 4.8 kbps
96: 9.6 kbps
192: 19.2 kbps
2.4 (
24
)
4.8 (
48
)
9.6 (
96
)
19.2 (
192
)
9.6
kbps
3-24
P17
Communications data
length
Used to set the data length.
7: 7 bits
8: 8 bits
7 (
7
)
8 (
8
)
7
bit
3-24
P18
Communications stop
bits
Used to set the number of stop bits.
1: 1 bit
2: 2 bits
1 (
1
)
2 (
2
)
2
bit
3-24
P19
Communications parity
Used to set the parity.
non: None
evn:
Even
odd: Odd
non (
non
)
evn (
evn
)
odd (
odd
)
evn
None
3-25
P20
Parameter initialization
Initializes the parameter set values
(except for the accumulated operat-
ing time) when “ini” is selected.
ini (
ini
)
abt (
abt
)
abt
None
3-22
P21
Accumulated operating
time clear
Clears the accumulated operating
time to zero when “ini” is selected.
ini (
ini
)
abt (
abt
)
abt
None
3-23
Display
Name
Description
Setting
range (See
note 1.)
Default
setting
Unit
Refer-
ence
Summary of Contents for EasySpeed 3G3JE
Page 1: ...3G3JE Compact Simplified Inverters Cat No I547 E1 02 USER S MANUAL...
Page 3: ...USER S MANUAL 3G3JE Compact Simplified Inverters...
Page 18: ...Table of Contents XVI...
Page 19: ...Chapter 1 Overview 1 1 Functions 1 2 Nomenclature...
Page 23: ...Chapter 2 Design 2 1 Installation 2 2 Wiring...
Page 86: ...Chapter 3 3 26 Operation...
Page 100: ...Chapter 4 4 14 Maintenance Operations...
Page 101: ...Chapter 5 Specifications 5 1 Inverter Specifications 5 2 Option Specifications...
Page 112: ...Chapter 5 5 12 Specifications...
Page 113: ...Chapter 6 Parameter Tables...
Page 118: ...Chapter 6 6 6 Parameter Tables...
Page 130: ...Chapter 7 7 12 Appendix...
Page 132: ...R 2 Revision History...